Cool roof coating · Factory and warehouse roofs
Metal-roof workshop at 40 °C?Measured 6–12 °C cooler inside on most projects
We coat the roof from the outside with a heat-reflective system that sends sunlight back before it heats the building. Once applied it uses no electricity, and the plant keeps running while we work.
- Solar reflectance 0.86, emissivity 0.90 (third-party tested)
- Applied from the outside of the roof — no shutdown
- Cooling target written into the contract on projects we install
- Buy the coatings with full technical support
- 6–12 °C
- cooler indoor air (measured on most projects)
- 25 °C+
- cooler roof surface (measured)
- 0
- electricity used once applied
- 130,000 m²
- of roof on two Huawei warehouses
Measured before work and after completion
Each pair is a thermometer-hygrometer reading inside the building, about 1.5 m above the floor: one before work and one after completion, on a day with similar weather.
-
↓8.0 °C workshop air
40.8 °C 32.8 °C
Ludao Precision Machinery · Heshan, Jiangmen
8,500 m² · 4 days · 2019
Roof surface 72.6 °C → 42.2 °C
-
↓11.3 °C workshop air
44.9 °C 33.6 °C
Hunan Baoguang Auto Parts · Liuyang
9,000 m² · 7 days · 2026
Roof surface 76.1 °C → 43.0 °C
-
↓13.0 °C workshop air
41.8 °C 28.8 °C
DuPont (Zhangjiagang)
8,600 m² · 8 days · 2025
Roof surface 71.9 °C → 39.7 °C
Air-conditioning on · sunny · 36 °C outside
-
↓12.4 °C workshop air
45.9 °C 33.5 °C
Shaanxi Baoguang Auto Parts · Baoji
9,000 m² · 7 days · 2026
Roof surface 77.5 °C → 36.0 °C
-
↓12.2 °C warehouse air
39.8 °C 27.6 °C
Weilong Park Phase II (Huawei warehouse) · Changping, Dongguan
62,000 m² · 12 days · 2020
Roof surface 74.6 °C → 44.5 °C
Air-conditioning on · sunny · 36 °C outside
-
↓7.5 °C warehouse air
41.8 °C 34.3 °C
Goodman Boluo Logistics Park (Huawei warehouse) · Huizhou
68,000 m² · 15 days · 2021
Roof surface 71.4 °C → 44.7 °C
-
↓11.5 °C workshop air
41.8 °C 30.3 °C
Xiamen Faratronic
47,800 m² · 15 days · 2022
Roof surface 68.4 °C → 42.2 °C
Air-conditioning on · sunny · 36 °C outside
-
↓9.6 °C workshop air
41.4 °C 31.8 °C
Hilti (China) · Zhanjiang
16,000 m² · 7 days · 2023
Roof surface 71.2 °C → 42.8 °C
-
↓7.2 °C workshop air
43.9 °C 36.7 °C
Baoguang (Tianjin) Auto Parts
24,000 m² · 14 days · 2026
Roof surface 73.9 °C → 36.8 °C
Results differ from building to building — heat sources, ventilation and roof type all matter. Baoguang Tianjin has many heat-producing machines, so its drop is smaller. We measure your building before we specify.
Why fans and coolers can't hold back roof heat
Fans, evaporative coolers and air-conditioning deal with heat once it is inside. The coating stops it at the roof, before it gets in. On a summer afternoon a metal roof reaches 70–80 °C, and the air under it heats up from the top down.
- 1
Sunlight is reflected back
The 902 topcoat has a solar reflectance of 0.86 — most of the sunlight hitting the roof bounces off (CTC report WT2020B01C04600).
- 2
Absorbed heat is released to the sky
Hemispherical emissivity of 0.90: the heat the roof does absorb is radiated away as infrared, so the roof no longer bakes.
- 3
Still works when dirty
After soiling, reflectance changed by only 5% (the standard allows up to 20%). When dust builds up, rinsing with water restores it.
Already have fans, coolers or air-conditioning? Keep them. With the roof heat blocked, they run under less load.

Roof coating vs fans, coolers and air-conditioning
| Cool roof coating | Fans / evaporative coolers / air-conditioning | |
|---|---|---|
| Where the heat is handled | Stopped outside, at the roof | Blown around or cooled inside |
| Indoor air temperature | 6–12 °C lower on most measured projects | Fans: little change. Evaporative coolers: a few degrees, with higher humidity. Air-conditioning: works, but costly to buy and run |
| Electricity | None once applied | Runs — and bills — every day |
| Installation | Outside on the roof; production continues | Wall openings, ducts or pipework |
First, find out where the heat comes from
Workshop heat comes from the sun on the roof, from machines and from poor ventilation. We measure on site and specify for the building.
- 01 Mostly sun on the roof Single-skin metal roofs, hottest at 2–3 pm, hotter the closer you get to the roof. Roof coating has the biggest effect.
- 02 Lots of machine heat, poor ventilation Injection moulding machines, ovens: hot air collects at the top. Block the roof heat first, then add exhaust ventilation.
- 03 Furnaces, or an insulated roof already A concentrated heat source, or a thick insulation layer under the roof. We measure the heat sources first, then choose the build-up.
The system
Two or three products, all water-based and made in our own factory, applied by spray, roller or brush.
- 01
TYS-BIC560-901 primer
Seals the substrate, bonds the topcoat and blocks near-infrared heat at the base of the system. 1–2 coats, 0.17–0.25 kg/m² per coat.
- 02
TYS-TIC610 insulating mid-coat (optional)
For low roofs over hot processes: thermal conductivity 0.14 W/(m·K), adhesion 1.7 MPa (CTC report WT2023B01C01585). Applied in 2–3 passes.
- 03
TYS-BIC560-902 topcoat
Reflects sunlight and radiates heat away. 1–2 coats, 0.17–0.25 kg/m² per coat, cross-applied. White as standard.
Buying the coatings for your own crew or your customers?
No MOQ on standard products, 20 kg pails, ships 3–5 days after payment. We specify the system, calculate quantities and train your applicators by video.
Third-party test data: 902 cool roof topcoat
Every coating looks reflective when it's new. Ask any supplier three things: a third-party report number, both solar reflectance and emissivity, and how much reflectance is lost after soiling.
| Property | Standard requirement | TEYISHU 902 |
|---|---|---|
| Change in solar reflectance after soiling | ≤ 20% | 5% |
| Dirt pick-up resistance (lower is better) | Superior grade ≤ 15% | 9% |
| Solar reflectance | ≥ 0.80 | 0.86 |
| Near-infrared reflectance | ≥ 0.80 | 0.85 |
| Hemispherical emissivity | ≥ 0.85 | 0.90 |
| Water resistance | 96 h, no defects | 96 h, no defects |
| Alkali resistance | 48 h, no defects | 48 h, no defects |
| Scrub resistance | 2,000 cycles, film intact | 2,000 cycles, film intact |
National Building Materials Testing Center (CTC Group), report WT2020B01C04600 — tested to GB/T 25261-2018 (reflective flat topcoat) and GB/T 9755-2014 (superior grade). All items passed. Test sample: TYS-BIC560, white.
Questions buyers ask
How many degrees cooler will my building be?
Does the plant need to stop while you work?
How long does it last? Does it still work when dirty?
Isn't radiative cooling or aerogel coating better?
Can our own contractor apply it?
How is it priced?
What are the application conditions?
Send roof photos — we'll tell you what the roof needs
Tell us what you need. Photos of the roof help us answer faster.
- Project enquirySend roof photos, the area, the location and how hot it gets inside. We'll tell you whether a cool roof suits the building and how we'd build it up.
- Product enquiryKnow the product? Ask for a price. Not sure? Tell us the use and the area and our engineers will specify it.
We reply by email within one working day.