How we measure

How we measure cooling

Every temperature on this site is a site reading from a named project, taken before work and after completion. This page shows what we measure, how, and how to read the numbers.

6–12 °C
cooler indoor air (measured on most projects)
25 °C+
cooler roof surface (measured)

Three temperatures, measured separately

A single "up to" number tells you little. We record three temperatures, because each answers a different question.

  • Roof surface Infrared thermometer Roof surface Read at the same positions on the roof before and after coating. Shows how much solar heat the coating keeps off the roof.
  • Roof underside Infrared thermometer Roof underside Measured from inside the building, aiming up at the underside of the roof sheet. Shows how much heat still comes through the roof.
  • Indoor air Thermo-hygrometer Indoor air Hung about 1.5 m above the floor, recording the daily maximum, compared with a day of similar weather before the work. This is the temperature your people and machines actually work in.

How a reading is taken

  1. 01

    Fix the points at the survey

    During the site survey we choose the measuring points, photograph them and take the first readings before any work starts.

  2. 02

    Same instrument, same points

    After completion we measure again at the same points with the same instrument.

  3. 03

    Compare like with like

    We compare days with similar weather. Where part of the roof is still uncoated, we can also compare coated and uncoated areas on the same day.

  4. 04

    Record and hand over

    Readings are photographed and go into the acceptance records you receive at handover.

Readings from named projects

Indoor air, measured before work and after completion. The roof surface reading is shown where we recorded it.

  • Ludao Precision Machinery · Heshan, Jiangmen

    ↓8.0 °C workshop air

    40.8 °C 32.8 °C

    Ludao Precision Machinery · Heshan, Jiangmen

    8,500 m² · 4 days · 2019

    Roof surface 72.6 °C → 42.2 °C

  • Shaanxi Baoguang Auto Parts · Baoji

    ↓12.4 °C workshop air

    45.9 °C 33.5 °C

    Shaanxi Baoguang Auto Parts · Baoji

    9,000 m² · 7 days · 2026

    Roof surface 77.5 °C → 36.0 °C

  • Weilong Park Phase II (Huawei warehouse) · Changping, Dongguan

    ↓12.2 °C warehouse air

    39.8 °C 27.6 °C

    Weilong Park Phase II (Huawei warehouse) · Changping, Dongguan

    62,000 m² · 12 days · 2020

    Roof surface 74.6 °C → 44.5 °C

    Air-conditioning on · sunny · 36 °C outside

  • DuPont (Zhangjiagang)

    ↓13.0 °C workshop air

    41.8 °C 28.8 °C

    DuPont (Zhangjiagang)

    8,600 m² · 8 days · 2025

    Roof surface 71.9 °C → 39.7 °C

    Air-conditioning on · sunny · 36 °C outside

  • Hunan Baoguang Auto Parts · Liuyang

    ↓11.3 °C workshop air

    44.9 °C 33.6 °C

    Hunan Baoguang Auto Parts · Liuyang

    9,000 m² · 7 days · 2026

    Roof surface 76.1 °C → 43.0 °C

  • Baoguang (Tianjin) Auto Parts

    ↓7.2 °C workshop air

    43.9 °C 36.7 °C

    Baoguang (Tianjin) Auto Parts

    24,000 m² · 14 days · 2026

    Roof surface 73.9 °C → 36.8 °C

Baoguang Tianjin has many heat-producing machines inside, so its drop is smaller. Heat sources, ventilation and roof type all change the result — that is why we measure your building before we specify.

See all projects

How to read the numbers

  • Indoor air: 6–12 °C on most projects This is the range measured on most of our completed cool roof projects with the 901 + 902 system on single-skin metal roofs. Buildings with strong internal heat sources see less.
  • Roof surface: 25 °C+ cooler The roof surface drops much more than the indoor air. A large roof-surface number on its own does not tell you how much cooler the workshop will be.
  • Lab data, separately Solar reflectance 0.86 and emissivity 0.90 come from a third-party laboratory (report WT2020B01C04600), not from site readings. We keep the two apart.

On projects we install, the target is in the contract

  • Cooling target in writing Measuring points and the cooling target are agreed and written into the contract — typically roof surface 20 °C or 25 °C cooler, and indoor air generally not less than 5 °C cooler.
  • Full refund if the target is missed After completion we re-measure at the same points on a day with similar weather. If the agreed target is not met, you get a full refund.
  • Final payment after re-measurement The final payment is made only after the re-measurement. This applies to projects installed by our own crews.

Questions buyers ask

Why do other suppliers quote 20 °C or 30 °C?
Those figures are usually roof-surface readings, sometimes under a heat lamp rather than sunlight, and usually the best single result. Ask which temperature it is, where and when it was measured, and what it was compared with.
Can you measure my building before I decide?
For projects we install, yes — readings are taken at the site survey. For coating orders from outside China, we can tell you how to set up the same before-and-after measurement on your own roof.
Will my building get the same result?
Not necessarily. Single-skin metal roofs with little insulation and few internal heat sources gain the most. Insulated roofs, or buildings full of furnaces and machines, gain less.

Want to know what your roof would gain?

Send roof photos, the area, the location and what the building is used for.

  • Project enquiryTell us about the building and how hot it gets inside. We'll tell you what we would measure and what result to expect.
  • Product enquiryBuying the coatings? Tell us the roof type and area and we'll specify the system and quantities.

We reply by email within one working day.

I need
Problem (tick all that apply)
Tap to choose photos, or drag them here

We use your details only to answer this enquiry.